Section
10 |
Radio Equipment of Fixed Stations Forming
a Communication System Using Subscriber Radio Access Communication,
or Radio Equipment of Radio Stations that Perform Communication,
etc. for Testing Subscriber Radio Access Communication Equipment |
|
(Radio Equipment at a Fixed Station that Performs 1,900
MHz Band Subscriber Radio Access Communication, and that Performs
Communication, etc. for Testing 1,900 MHz Band Subscriber Radio Access
Communication Facilities) |
Article 58.2.13. |
Radio equipment at a fixed station that performs 1,900 MHz band
subscriber radio access communication and that is connected to terminal
equipment or customer-provided telecommunications facilities shall
satisfy the conditions defined in the items below:
1) |
General conditions
a |
The communication method shall be time division duplex
operation using time division multiple access. The number
of channels per carrier for time division multiple access
and the frame configuration for time division duplex operation
shall be, however, as announced separately (*) by the
Minister of Public Management, Home Affairs, Posts and
Telecommunications. |
b |
The carrier sensor to be supported shall comply with
the terminal conditions announced separately (*) by the
Minister of Public Management, Home Affairs, Posts and
Telecommunications. |
c |
If emission is continued owing to the failure of radio
equipment, the emission shall be stopped automatically
before the duration of the emission reaches 60 seconds. |
|
2) |
Conditions for the transmitter
a |
The modulation method shall be QPSK which shifts the
reference phase /4
every 2 bits. |
b |
Modulation shall be accompanied by band limitation of
50% roll-off on the transmission side, provided that the
roll-off rate is 0.5. |
c |
When a standard coding test signal having the same transmission
rate as that of a modulation signal is used for modulation,
the adjacent channel leakage power radiated in a band
of ±96 kHz with respect to the frequency distant
from the carrier frequency by 600 kHz or 900 kHz shall
be 800 nW or less, or 250 nW or less, respectively. |
d |
While no carrier is sent during communication, the leakage
power shall be 80 nW or less. |
e |
The modulation signal shall consist of pulses, and its
transmission rate shall be 384,000 bits/s (with a tolerance
of 100/1,000,000). The transmission rate of a signal which
consists of pulses converted from, for example, voice
shall be, however, as announced separately (*1) by the
Minister of Public Management, Home Affairs, Posts and
Telecommunications. |
f |
The antenna power shall be 0.08 W or less. |
g |
The antenna shall provide an absolute gain of 22 dB
or less. When the effective radiated power is equal to
or lower than the value generated when an antenna power
of 0.08 W is applied to an antenna with an absolute gain
of 22 dB, however, this value shall be compensated for
by the antenna gain. |
h |
The frequency of emissions to be sent shall be selected
automatically by sending emissions for a fixed station
as the remote station. |
|
|
2 |
Radio equipment at a fixed station for communicating with
a fixed station connected to terminal equipment of customer-provided
telecommunications facilities or at a radio station that performs
communication, etc. for testing 1,900 MHz band subscriber radio
access communication equipment shall comply with the conditions
defined in the items below, as well as the conditions defined
in items 1) b and c, and items 2) a to e in the previous paragraph.
1) |
For transmission to a fixed station connected to terminal
equipment or customer-provided telecommunications facilities
from a fixed station for communicating with a fixed station
connected to terminal equipment or customer-provided telecommunications
facilities, or for transmission to a fixed station for
relaying 1,900 MHz band subscriber radio access communication
from a fixed station for communicating with a fixed station
connected to terminal equipment or customer-provided telecommunications
facilities (excluding a fixed station for relaying 1,900
MHz band subscriber radio access communication), the communication
method shall be time division duplex operation using time
division multiplexing. For transmission to a fixed station
for communicating with a fixed station connected to terminal
equipment or customer-provided telecommunications facilities
(excluding a fixed station for relaying 1,900 MHz band
subscriber radio access communication) from a fixed station
for relaying 1,900 MHz band subscriber radio access communication,
the communication method shall be time division duplex
operation using time division multiple access. The multiplex
count in time division multiplexing, the number of channels
per carrier for time division multiple access, and the
frame configuration for time division duplex operation
shall be, however, as announced separately (*) by the
Minister of Public Management, Home Affairs, Posts and
Telecommunications. |
2) |
The antenna power shall be 0.16 W or less. |
3) |
The antenna shall provide an absolute gain of 22 dB
or less. When the effective radiated power is equal to
or lower than the value generated when an antenna power
of 0.16 W is applied to an antenna with an absolute gain
of 22 dB, however, this value shall be compensated for
by the antenna gain.
|
|
|
|